Nhoneywell s8600m ignition control module pdf download

Low cost replacement hsi control for honeywell, robertshaw and white rodgers singledual rod sensing capabilities for gas fired furnaces, boilers and other heating appliances switch selectable lockout times, ignition trials works with both natural and lp systems diagnostic led to aid in troubleshooting. For businessonly pricing, quantity discounts and free shipping. Heat not working honeywell s8600h ignition module the problem. Honeywell ignition controls with more than a decade of service in the field, the s8610u is time tested and proven. This module replaces honeywell s8600m ignition module. Replacement for honeywell furnace integrated pilot module. These ignition modules provide ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances. Honeywell s8600m ignition control module continuous retry. Honeywell s8610u universal intermittent pilot module. Honeywell s8600f replacement issues trouble free pool. Jan 23, 20 honeywell s8600m igniter manual reset answered by a verified hvac technician we use cookies to give you the best possible experience on our website.

Your local home and building control sales office check white pages of your phone. Used module to replace honeywell s8600m igniter module that had no vent damper plug see instructions in a kenmore power miser 80 furnace that was installed in 1990. Honeywell s8610u3009 universal intermittent pilot control for use in single or dualrod remote sense applications. These applications require honeywell residential division.

Check for 24 vac across pvmvpv terminals on module. The s8610u control provides ignition sequence, flame. With johnstone, you can stay current on product and technology changes, in addition to programs that make it easy for the contractor. Honeywell universal intermittent pilot ignition module that provides 24 volt control of pilot ignition on gas fired furnaces and boilers with a 15 second lockout time. I am replacing a johnson controls pilot gas ignition control unit with a honeywell 8610u and i am a little confused on how to connect all the wires. The s8610u3009 is the same as international comfort products part number 1005651. After approximately 90secs the fan start of course with no heat. Replacement for honeywell furnace integrated pilot module ignition control circuit board s8600m 1006 5. Make sure the maximum ambient temperature at the control locations will not exceed the rating of the control. My heater stopped working well the fan works but there is no heat and i called a heating and air man to check it and was told that the primary circuit board had to be replaced. Honeywell s8600m ignition control module continuous re. Honeywell q7300a installation instructions manual pdf download. Honeywell s8670k3000b 2 rod intermittent pilot control, 24 volts. The wiring on the johnson controls unit is as follows.

View and download honeywell s8610u installation instructions manual online. I replaced the honeywell s8610m ignition module with the new s8610u module attaching lead to lead in the same sequence. Honeywell s8610u3009 ignition module 1 hvac parts online. Universal hot surface ignition module replaces multiple fieldinstalled hot surface ignition modules supplied by honeywell, whiterodgers, robertshaw and johnson. This module is a universal replacement and has replaced over 300 honeywell part numbers.

For this system, the vk41vk81 series gas controls have been designed to have the s45657585 series. Dust or grease accumulation heavy accumulations of dust or grease can cause controls to malfunction. Honeywell pilot module s8600h s8600m s8610a s8610b furnac ignition control board. Honeywell s8610u3009 universal intermittent pilot ignition module. Honeywell intermittent pilot module control board s8610m. The s8610u universal replacement ignition module is. This board is an upgraded replacement for many older honeywell controls control boards. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct. Honeywell intermittent pilot module control board s8610m s8610h s8660k s8660j this is a brand newuniversal furnace intermittent pilot gas ignition module. We even have replacement furnace control boards that replace oem control boards. We have an ignition cable larger in diameter than found here ask your own hvac question customer. This aftermarket board made in the usa replaces all honeywell control boards with the models listed below including boards manufactured by honeywell robertshaw johnson controls penn controls. View online or download honeywell v8600d application. View and download honeywell q7300a installation instructions manual online.

Page 3 we recommend mounting the module with the terminals cable must be no longer than 36 in. A nema 4 corrosive chemicals can also attack the module and gas enclosure. Honeywell, robertshaw, johnson controls, and others. Where dust or grease can be a problem, provide covers for the module and the gas control to limit contamination. The strange thing is that if i hook up my old s8600f everything works just fine, when i install the s8610u i get nothing. In 2002 alpine home air products became the first company to sell heating, air conditioning and indoor airquality products online. The super tradeline s8610u universal intermittent pilot gas ignition control module is designed to provide easy field replacement of a wide range of intermittent pilot ignition modules manufactured by honeywell, robertshaw, johnson controls, and others. Part type ignition control module part number s8600m additional board numbers 974152 rev a known compatibility carrierhoneywell warehouse location 4c5 important. Repair honeywell s8600m error codes windows 10, 8 7.

New honeywell universal electronic ignition gas control valve. Once you get the problem fixed you may need a new control. Heat excessively high temperatures can damage controls. Universal intermittent pilot module industrial controls. Please confirm that your configuration uses this part prior to purchase. S8610u3009 universal intermittent pilot gas ignition control. The combined valve and ignition system cvi has specially been developed for application in gas fired appliances with either intermittent pilot or direct burner ignition. Feb 06, 2011 will a honeywell s8610u work for a honeywell s8600m. This is a brand new honeywell universal intermittent pilot gas ignition module. Honeywell ignition control components grainger industrial.

Click the icon or the document title to download the pdf. Replacement household furnace control circuit boards. Ignition module, hot surface ignition, lead length in. Honeywell pilot module s8600h s8600m s8610a s8610b furnac. Lockout spark and pilot gas on until lightoff or trial for ignition ends. Has 100% shut off with 90 second ignition trial and 6 minute delay before retry. Honeywell universal pilot ignition module, used with.

Honeywell s8610u3009 intermittent pilot control lesman. To change out a the igniter, flame sensor and ignition. Page 4ground control system and the 24v terminal on the module. Field service replacement for most honeywell, robertshaw, johnson, and utec hsc intermittent pilot ignition modules. You can replace more than 300 competitive models with the s8610u and know that honeywells long history of quality and reliable service is working for you. Sp10763c rheem sp10763c s8600m4009 ignition module 24v. Johnstone supply is a leading wholesale distributor for multiple leading brands of hvacr equipment, parts and supplies available and instock at local branches. Teledyne laars minicombo ii mctmcs jvs 050 jvs 075 jvs 100 jvs 125 jvs 160 jvs 225 honeywell s8610m3017 ignition module, continuous retry our price. I ordered a honeywell s8610u which should be a direct replacement for my s8600f but after replacing all the wires and installing the new control unit i am not getting any spark and the pv light on my control board is not lit. S8610u universal intermittent pilot module honeywell. Provides electronic control of most intermittent pilot ignition systems used on gasfired furnaces, boilers, and other heating appliances. Our line of gas appliance controls include gas solenoid valves for.

Apr 08, 2015 honeywell s8600m not sparking answered by a verified hvac technician we use cookies to give you the best possible experience on our website. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. Track page views with auctivas free counter 121698497036. The s8610u 3009 honeywell furnace ignition control module is brand new and comes in a honeywell oem factory parts box. For my furnace, which does not have a power damper, the lead that went to the contact on the old module marked 24v now goes to the contact marked thw. Intermittent pilot modules provide electronic control of intermittent pilot ignition systems used on gasfired furnaces, boilers and other heating appliances. Universal intermittent pilot ignition module replaces multiple field installed intermittent pilot modules supplied by honeywell, robertshaw, johnson, and utec hsc. S8610u3009 universal intermittent pilot gas ignition control intermittent pilot. Honeywell s8600m ignition control module continuous retry 100% shutoff.

Honeywell s8610u3009 pilot control field service replacement. S8610u3009 honeywell furnace ignition control module. I read nothing across the mv to mvpv or the pv to mvpv leads. Check electrical connections between module and pilot operator on gas control. Dec 07, 2008 heat not working honeywell s8600h ignition module the problem. Intermittent pilot gas ignition control module is designed to provide easy field. Rheem sp10763c s8600m4009 ignition module 24v s8600m4009 ignition module 24v.

Most manufacturers ship their products in multiple configurations. Honeywell s8910u universal hot surface ignition module. The system model number is nug5075bfa2 it is a tempstar with a honeywell module. Includes instructions and accessories for easy replacement. Icm controls icm290a ipi gas ignition control replacement for popular models, including honeywell s8610u3009. Use honeywell ignition cable or construct an ignition. Includes cross reference, instructions, and accessories for easy. Check continuity of ignition cable and ground wire.

Honeywell s8600m honeywell ignition control module honeywell s8600m continuous retry, auto ignition systems, 24v, 60 hz. Low cost replacement hsi control for honeywell, robertshaw and white rodgers singledual rod sensing capabilities for gas fired furnaces, boilers and other heating appliances switch selectable lockout times, ignition trials works with both natural and lp. Main valve 1 other control 2 pilot valve 3 flame sensor 4 red wire from transformer 6. Replacement for honeywell furnace integrated pilot module ignition. Honeywell pilot module s8600h s8600m s8610a s8610b furnac ignition control board this is a brand new honeywell universal intermittent pilot gas ignition module. Provide electronic control of intermittent pilot ignition systems used on gasfired furnaces, boilers and other heating appliances. This module replaces a wide range of intermittion pilot ignition modules manufactured by honeywell, robertshaw, johnson controls, penn con. Continuous retry trial time with configurable lockout of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge.

Add the current draws of all other devices in the control circuit, including the pilot and main valves in the gas control, and multiply by 24 to determine the total va requirement of these components. Functional equivalent of s86, s8600, s8610 and s90 modules. These ignition modules provide ignition sequence, flame monitoring and. Make sure the maximum ambient temperature at the control does not exceed the rating of the control.

Checked and found the problem to be a broken wire to the connector for the ventdamper on the honeywell s8610m ignition module. Honeywell s8610u3009 intermittent pilot control field service replacement for most honeywell, robertshaw, johnson, and utec hsc intermittent pilot ignition modules. Make sure the maximum ambient temperature at the control does not exceed the rating of the. Heat the controls can be damaged by excessively high tem peratures. Replacement for honeywell furnace integrated pilot module ignition control circuit board s8600m 1006. No wiring had to be changed except 24 volt wire went to thw terminal in new module as indicated in the instructions. Replacement for honeywell furnace integrated pilot module ignition control circuit board s8600m. Couldnt get you honeywell s8610h she told me, crimped into the terminal that was screwed to the pilot burner bracket. Honeywell s8610u installation instructions manual manualslib. Replacement is little tricky because the old module s8600m was wired differently. The 8600 family of ignition controls provide ignition sequence, flame monitoring and safety shutoff for intermittent pilot.

Honeywell f8600h ignition module alpine home air products. Icm controls icm290a ipi gas ignition control replacement for. Due to high demand for honeywell ignition module, hot surface ignition, lead length in. I read 24vac at the 24v input on the s8600h module. When pushing against the ventdamper connector on the module the boiler would fire. A nema 4 enclosure is recommended for the ignition module. When i turn my heat on and a call for heat is sent. Contains all the essential wiring diagrams across our range of heating controls.

1059 185 1555 1063 585 149 675 1142 366 19 1651 320 1280 1297 391 1616 717 1019 33 1139 245 263 786 131 338 514 1234 173 210 348